I am a simple structural engineer and I am looking for some help in designing a HDPE pipe under pressure for a hydro power penstock.
We have designed these pipelines as a soil structure interaction using a 3D stick model with springs modelling the soil to determine the axial and bending stresses due to the pressure from the water column of the pipe and add them to the hoop stress. Typically these penstocks are from steel pipe where the interaction between the principal stresses in the pipe is very well defined and can be added with a Von mises formula.
Since for this project we are looking at the cheaper option of using HDPE pipe the process is a little different.
The initial modelling is the same to get the axial and bending stresses in the pipe and then there is the calculated hoop stress but the interaction between stress due to pressure (hoop) and axial (tension and bending) does not appear to be very well defined?
Looking through the PPI information they have a very simple equation where they limit the bending stresses to 1/8 of the hydrostatic design stress (HDS) but they do not show any interaction with the hoop stress?
Can I be at 99.9% efficient in hoop stress or operating pressure and still put bending into the HDPE up to the 1/8 HDS?
1/8 HDS seems pretty low, what about if the axial stress was fully in tension? Can I pressure the pipe to 99.9% operating pressure with a blind flange on the end so there is also quite a high tension load and how do these stresses interact?
Thanks for any info Hi Bimr,
I have read through the design guide and while it has some interesting information it is pretty simplified and looks at buried pipe in a trench only and does not really dress the actual soil structure interaction and the stresses in the pipe itself.
Consider the example in the attached sketch where the pipe is DR 7 (so quite stiff) and the embankment is of a quite low stiffness, perhaps an fill compacted around the pipe that is not able to support too much lateral load. If the DR pipe is at close to its maximum operating pressure and the pipe gets around an outside bend there is considerable thrust outwards and the soil structure interaction rely heavily;y on the pipe itself in bending to support this thrust and we would get a bending moment something like what is shown (there could also a net axial load which could be T or C dependant on the global configuration of the system).
In steel, we could add the hoop tension stress with the axial stress associated with the bending using the Von Mesis formula to ensure the overall stress is below the allowable steel limits. But with the HDPE i am not too sure how to consider the interaction between the different stress orientations. It is not enough to just say that the operating pressure is within the allowable range and since the pipe is buried there is not bending or axial stresses, there certainly could be and if not accounted for then we could get pipe failure.
First of all we don't use von Mises for pipeline design. Use hoop stress, axial stress, bending and take them together to get an equivalent stress (different than von Mises). The allowable for the equivalent stress has an appropriate safety factor such that more complicated stress combination methods are not needed.
The fill in the trench should be adequately compacted, but even if not, it will usually compact itself quite well around the pipe in a short time. Use long natural bending radaii at bends to minimize concentrated outward thrusts. A long radius bend distributes outward thrusts along its entire length. I would be very surprised if the soil on the side of a trench gave way and the pipe climbed out of the trench. I suppose it could happen, but I've never seen that happen on any ambient temperature pipeline. At most you might get some ovaling of the pipe.
I've already said that, if the pipe is buried, you won't get much if any axial tension, at least as long as the temperature does not drop a lot. At normal or slightly elevated temperatures, you will have compression, if anything. Hi BigInch,
Thanks again for more info.
Just to confirm, you would take the induces stresses in the pipe, hoop and axial (from both axial and flexure) and add them linearly and if this artificial total stress is under the equivalent allowable stress in the pipe based on HSD, temperature etc. then the pipe is acceptable? I am assuming that the different surges conditions can also be done this way using the modified limits?
I would like to ask you another question, Consider a hypothetical situation where the same HDPE pipe is on an outside bend but is not buried, now for sure there is both axial and hoops stresses. Under these conditions you would still use the same artificial total stress addition?
Thanks again for your help,
BI,
I assume you're still in New Year fug here "Natural gas pipelines can have a 10% overstress for surge conditions, liquid hydrocarbon pipelines not." - Surely the other way around??
Either way, every name, I suggest you look at all the other chapters in the plastic pipe link BIMR sent you. chapter 3 might answer some of your questions.
I think you're over complicating this, but to be a little fair, you appear to be in the twilight zone between a fully restrained system and your slightly odd surface laid with a bit of soil on top system with bends which is neither fully restrained nor unrestrained like a piping network. that's why you analyses it normally using Caesar or similar pipe stress analysis.
PE has quite a high Poissons ration (~0.45), but a large thermal co-efficient. It also exhibits elasto-plastic creep properties under long term stress, so it's not the same as steel.
I still don't get where your " pipe gets around an outside bend there is considerable thrust outwards" considerable thrust comes from where exactly??. Any force is resisted by the restrained part of the pipeline so the actual movement is low. This in one reason you don't really want or need thrust blocks because the movement is so low, but forces could be high if you try to prevent any movement.
It would be good to see some numbers here so we can figure out if you're exceeding the guidelines you mention.
I believe that yes, you can be at the max pressure rating of the pipe with a blank end. PE pipe has a substantial design factor built in.
Usually the biggest issue with PE pipe is thermal growth / stress between as-laid temperature and operating temperature - this is 10 X steel rates so can become quite significant, in either direction.
Remember - More details = better answers
Also: If you get a response it's polite to respond to it. I kind of scanned this exchange and I think there's a lot of valuable information. But my basic question is: What are you cheapening a penstock design? These are systems that need to last a thousand years with little or no attention. Failures are disastrous. Do you want to find out 10 years out that HDPE ages or deteriorates in an unexpected way? We have enough problems with concrete and steel pipes, why experiment? And how much are you going to save, especially considering the total cost of the project? One percent? Three percent?
There's a bunch of residential pipes in the Phoenix area called Orangeburg. I'm sure it was the latest, greatest (and cheapest) pipe you could find. Now it's being replaced, stick by stick. But think of the money saved! Hi All,
Thanks you for your comments.
I have been in contact with the PPI, and the rep I spoke to was yet to be able to confirm how they establish their combined stress criteria. They were very helpful and are in the process of digging a little deeper. Once I have an answer from them I will post here.
To answer a few of the question/comments above:
LittleInch: We are in preliminary design so I don't have the bending stress components but operating pressure is around 333 psi (so near the max for DR 7.3 pipe!). Yes we certainly are living in the gap between fully and fully un restrained pipe, thats why I have the questions! The trust comes from the water column pressure and the change in direction of the bend. I agree with a quite large bend radius this thrust will be spread over a large soil area, but as you could see we only have a small amount of soil on the edge of our mountain track where the pipe is being laid.
If i consider the basically the full rated pressure and then a blind plane I get something like (back of the envelope)
Hoop from pressure = 5.9 MPa (856 psi)
Axial from pressure on blind flange) = 2.4 MPa (348 psi)
So if i directly combine these stresses => 5.9 + 2.4 = 8.3 MPa ( psi)
So this is larger than the presumed allowable of psi or 6.9 MPa.
Jed and BigInch: I don't think we "cheapening" the penstock. If the HDPE can take the required loading and is a less expensive alternate then I think we are providing the best economical solution. This is not a major infrastructure project for a large municipality, it is a micro hydro looking to produce small amounts of off grid power, it needs to be low cost to be economical enough to build.
What I am trying to see is if I could use HDPE for the whole length vs using it for some and then switching to steel when the pressure increases. If we can stay with HDPE and back it with some sound engineering practices and judgements and we can same money then I think we have down our job. If not we will use the steel and the project cost go up, but nothing we can do!
Thanks again for all the comments, very helpful.
HDPE Pipe for Water: FAQs Answered - Bausano
Exploring the Growing HDPE Pipe Market
HDPE Pipe Market will grow at a 5% compound annual growth rate during the forecast period -. HDPE pipes are made of polyethylene resin and is a tough, durable material with unique performance properties that allow for its use in a broad range of applications like for transport of oil, gas, water, sewage or for Agriculture & Irrigation. For example, the developing countries are aggressively working on the development of their sewage system, thus the demand of HDPE pipes has also increased. Also, companies from oil & gas industry are trying to adopt the HDPE pipes as an alternative of steel pipes for the inferior cost and high tensile strength and easy handling.
These are not the only advantages of HDPE. For example it is resistant to corrosion, deposits, and tuberculation. HDPE is easy to transport, it is durable but also recyclable. HDPE pipes are flexible thanks to the many joining options, so it is not needed to use flames for joining the pipes. The material used for pipes is critical for the success of the project and HDPE is the right material for that!
The purpose of this technical note is to provide answers to commonly asked questions about use of HDPE (high density polyethylene) piping systems for water applications.
Valor Pipe supply professional and honest service.
What is the life expectancy of HDPE pipe in water applications?
Many installations of HDPE pipe in water applications are already reaching 50 years of successful service. The polyethylene pipe industry estimates a service life for HDPE pipe to conservatively be 50-100 years. This relates to savings in replacement costs for generations to come.
Will HDPE pipe float in water?
Yes, HDPE pipe, due to its density being slightly less than water, will float even when full of water. When it is desired to ensure flotation of the line, various forms of collars, saddles, and strap-on flotation devices are available. For underwater anchored pipeline installations, it is important to specify the proper weights and spacing of the weights. Screw-anchors are a practical alternative. Whenever possible, an underwater pipeline should be installed in a trench with protective crushed rock cover.
If you want to learn more, please visit our website 36 Inch HDPE Pipe.
How does the impact strength of HDPE compare with other pipes?
HDPE is a ductile material and has exceptional impact strength. HDPE’s superior impact strength provides a piping system that is near impervious to impact damage and to damage from improper tapping. In the real world, engineers understand that pipes must be tough and resist impact and handling damage. HDPE pipes are field tested and proven to be impact tough.
How is HDPE pipe connected and joined to PVC pipe?
Methods of joining HDPE pipe to PVC pipe vary with the size and style of PVC. Common methods include slip-joint anchor fittings, gasketed joint adapters, and flange connections. HDPE to PVC transition fittings are also available from certain fittings manufacturers; also, refer to PPI TN-36, General Guidelines for Connecting HDPE Potable Water Pressure Pipes to DI and PVC Piping Systems, for additional information.
For more HDPE Pipe Priceinformation, please contact us. We will provide professional answers.